Water System Details

Community: STOCO MUTUAL WATER COMPANY
County: Kern
Sys. Category: Complete water and wastewater systems
Agency Name: STOCO MUTUAL WATER COMPANY
Ownership:
Ownership Type:
Population: 70
Connections: 6
2010 MHI: 91,053
SDAC or DAC: Non-DAC
DAC Classification Source: Calculated

IRWMP: KERN
Geography: Valley Floor
Location: Bakersfield

Contact Title: c/o Stockdale Prop. Management
Contact: Michelle Bicera
Phone:
Alt. Contact:
Phone:

H2O Sys. Num.: 1500517
Water Source: not specified
Active Wells Count: 1
Wells Issues?: XXXXX
Issues: This well is at least 35 years old. There is no alternative source for the users at this location other than the 10,000 gallon pressure tank. This second well would be designed to have the same capacity as the existing well and act as a back up in case

Potential Solutions:

  Water quality sample results for selected constituents. Values shown for water samples collected 2004-2014.
  Raw Water Delivered Water   Raw Water Delivered Water
  Max. Ave. Count Max. Ave. Count   Max. Ave. Count Max. Ave. Count
Arsenic (10 ug/L): 5.90 4.05 2 5.90 4.05 2 Flouride (2 mg/L): 0.14 0.10 2 0.14 0.10 2
DBCP (0.2 ug/L): 1.00 0.51 2 1.00 0.51 2 Perchlorate (6 ug/L): 4.00 4.00 3 4.00 4.00 3
Nitrate as NO3 (45 mg/L): 18.80 9.22 5 18.80 9.22 5 TCE (5 ug/L): 0.50 0.50 1 0.50 0.50 1
PCB (0.5ug/L): 1 1 THMs (80 ug/L): 3.60 2.80 1 3.60 2.80 1
Uranium (20 pC/L): 1.70 1.70 1 1.70 1.70 1              

WW Sys. Num.: 257951
Treatment: XXXXX
Design Flow (MGD): 0.05

Total Enforcement Actns: 1
Cat.1 Viol: 0
Cat. 2 Viol: 0

Total Viol: 1

Septic Probs?: XXXXX
Sewer Issues:
Potential Solutions: Installations will require:MOBILIZATION, DEMO & PERMIT30" CONDUCTOR18 PILOT BOREHOLE & E-LOGREAM 26" HOLE & CAL LOG16" OD BLANK 5/1616" OD STD FLO LOUVERED 5/16"16" ODFULFLO LOUVERED 5/16"16" OD MILLSLOT 64 ROW 5/16"GRAVEL PACK / CEMENTAIRLIFT SWABINSTALL TEST PUMPTEST PUMP DEVELOPMENTTEST PUMP CONSTANTCONCRETE PUMP BASE100 HP PUMP, MOTOR, BOWL, HEAD, AND PIPING FROM THE HEAD TO THE PRESSURE TANKBACK-UP GENERATOR FOR POWER FAILURE 180 KW USED UNIT WITH 10,000 HOURS EQUIPMENTELECTRICAL CONECTIONS TO EXSISTING POWER TWO SLECTOR SWETCHES AND NEW PANNEL TO OPERATE EACH WELL SEPERATELY-Water Storage Tank-System does not meet the fire flow requirements set forth in the Kern County Development standards - (System has pressure tank only)Booster Pumps (excluding cement pads)Well Pump RetrofitMiscellaneous Piping (6-inch)6-inch Resilient Seated Gate ValveMagnetic Flow Meter (Inoperable)5/8" Water Meters (replace existing to properly quantify the amount of water being used with each connection)Back - up Generator/ATS (None)Instrumental/ControlsContingencies (15%)Engineering and Administrative Fees - Including Reports (10%)Permit and Legal FeesInstall pressure regulator and combination metering valve with check.Replace 10,000.00 gallon pressure tank.-Water Storage Tank - System does not meet the fire flow requirements set forth in the Kern County development standards - (System has pressure tank only)Booster Pumps (excluding cement pads)Well Pump RetrofitMiscellaneous Piping (6-inch)6-inch Resilient Seated Gate ValveMagnetic Flow Meter (Inoperable)5/8" Water Meters (replace existing to properly quantify the amount of water being used with each connection)Back - up Generator/ATS (None)Instrumental/ControlsContingencies (15%)Engineering and Adminstrative Fees - Including Reports (10%)Permit and Legal Fees-Water Storage Tank - System does not meet the fire flow requirements set forth in the Kern County development standards - (System has pressure tank only)Booster Pumps (excluding cement pads)Well Pump RetrofitMiscellaneous Piping (6-inch)6-inch Resilient Seated Gate ValveMagnetic Flow Meter (Inoperable)5/8" Water Meters (replace existing to properly quantify the amount of water being used with each connection)Back - up Generator/ATS (None)Instrumental/ControlsContingencies (15%)Engineering and Adminstrative Fees - Including Reports (10%)Permit and Legal Fees
Treatment Comm: XXXXX
SelfHelp Comments: